Creat membership Creat membership
Sign in

Forgot password?

Confirm
  • Forgot password?
    Sign Up
  • Confirm
    Sign In
Creat membership Creat membership
Sign in

Forgot password?

Confirm
  • Forgot password?
    Sign Up
  • Confirm
    Sign In
Collection
For ¥0.57 per day, unlimited downloads CREATE MEMBERSHIP Download

toTop

If you have any feedback, Please follow the official account to submit feedback.

Turn on your phone and scan

home > search >

Optimizing timing performance of CdTe detectors for PET

Author:
Nakhostin, M.  


Journal:
PHYSICS IN MEDICINE AND BIOLOGY


Issue Date:
2017


Abstract(summary):

Despite several attractive properties, the poor timing performance of compound semiconductor detectors such as CdTe and CdZnTe has hindered their use in commercial PET imaging systems. The standard method of pulse timing with such detectors is to employ a constant-fraction discriminator at the output of a timing filter which is fed by the pulses from a charge-sensitive preamplifier. The method has led to a time resolution of about 10 ns at full-width at half-maximum (FWHM) with 1 mm thick CdTe detectors. This paper presents a detailed investigation on the parameters limiting the timing performance of Ohmic contact planar CdTe detectors with the standard pulse timing method. The jitter and time-walk errors are studied through simulation and experimental measurements and it is revealed that the best timing results obtained with the standard timing method suffer from a significant loss of coincidence events (similar to 50%). In order to improve the performance of the detectors with full detection efficiency, a new digital pulse timing method based on a simple pattern recognition technique was developed. A time resolution of 3.29 +/- 0.10 ns (FWHM) in the energy range of 300-650 keV was achieved with an Ohmic contact planar CdTe detector (5 x 5 x 1 mm(3)). The digital pulse processing method was also used to correct for the charge-trapping effect and an improvement in the energy resolution from 4.83 +/- 0.66% to 2.780 +/- 0.002% (FWHM) at 511 keV was achieved. Further improvement of time resolution through a moderate cooling of the detector and the application of the method to other detector structures are also discussed.


Page:
N486---N506


VIEW PDF

The preview is over

If you wish to continue, please create your membership or download this.

Create Membership

Similar Literature

Submit Feedback

This function is a member function, members do not limit the number of downloads